RT Journal Article SR Electronic T1 Manchester repair. An alternative to hysterectomy JF Saudi Medical Journal JO Saudi Med J FD Prince Sultan Military Medical City SP 1473 OP 1475 VO 30 IS 11 A1 Abdulrahim A. Rouzi A1 Nora N. Sahly A1 Amal S. Shobkshi A1 Hassan S. Abduljabbar YR 2009 UL http://smj.org.sa/content/30/11/1473.abstract AB Local data regarding Manchester repair are not available in the current literature. We report a retrospective case series of 7 women who presented with uterine prolapse, and underwent Manchester repair from January 1997 to May 2008 at King Abdulaziz University, Jeddah, Kingdom of Saudi Arabia. All of these women were multiparous (para 3±1) and wanted to avoid hysterectomy, and become pregnant. The duration of the procedure was 119 ± 16 minutes. No operative complications were observed. The mean duration of follow up was 5±2 years. All of the women were satisfied with the procedure. Two (28.6%) patients subsequently became pregnant and had a successful vaginal delivery. Manchester repair is a valid alternative to hysterectomy for women with a second degree uterine prolapse who want to preserve their fertility.