PT - JOURNAL ARTICLE AU - Dongola, Nagwa A. AU - Gishen, Philip TI - Comparison between arthroscopy and 3 dimensional double echo steady state 3D-DESS sequences in magnetic resonance imaging of internal derangements of the knee DP - 2004 Jun 01 TA - Saudi Medical Journal PG - 761--765 VI - 25 IP - 6 4099 - http://smj.org.sa/content/25/6/761.short 4100 - http://smj.org.sa/content/25/6/761.full SO - Saudi Med J2004 Jun 01; 25 AB - OBJECTIVE: This study was performed with the aim of evaluating the usefulness of 3 dimensional double-echo steady state sequences in examining the internal derangements of the knee. Arthroscopy was used as a referral standard.METHODS: The study was performed in the Radiology and Arthroscopy Departments of King's College Hospital, London, United Kingdom, during a 6-month period from January 1997 to June 1997. All patients who had knee magnetic resonance imaging within 3 months of arthroscopy were retrospectively studied. Thirty-three patients fulfilled these criteria and were selected.RESULTS: Three dimensional double-echo steady state sequences produced sensitivity for detecting meniscal tears of 87.5% for medial menisci (MM) and 75% for lateral menisci (LM). Specificity was 76% for MM and 96% for LM; positive predictive value (PPV) was 46.1% for MM and 85.7% for LM and negative predictive value (NPV) of 95% for MM and 96% for LM. The sensitivity for the anterior cruciate ligament was 83.3%, specificity was 77.7%, PPV was 45.4% and NPV was 95.4%.CONCLUSION: Three dimensional double-echo steady state sequences are useful in evaluating internal derangement of the knee, especially in advanced cartilage lesions.