Table 1

- Studies on isolated porcine liver normothermic perfusion utilizing arterial pressure circuit control.8,9

AuthorPVHAPerfusion period
Butler, 20027.22 mmHg90.3 mmHg72 h
1.75 L/min240 ml/min
Schön, 200111 mmHg100 mmHg4 h
250 ml/min150 ml/min
St Peter, 20038 mmHg60-120 mmHg3 h
0.42 L/min0.18 L/min
Jakob, 19905-15 mmHg70-105 mmHg24 h
0.75 L/min0.25 L/min
Ghonem, 201118 mmHg100-130 mmHg3.5 h
350-475 ml/min150-220 ml/min
Echeverri, 20182-4 mmHg60 mmHg 
900-1200 ml/min400 ml/min
Boehnert, 201310 cm H2O60 mmHg12 h
950±110 ml/min365±85 ml/min
Banan, 201512±4 mmHg85±10 mmHg2 h
1.2±0.2 L/min0.5±0.1 L/min
He X, 20188-10 mmHg80-100 mmHg 
310-590 ml/min110-240 ml/min
  • PV: portal vein, HA: hepatic artery, h: hours, min: minute, L: liter, ml: milliliter, mmHg: millimeter mercuryn h: hours