Table 2

- Correlation analysis of aided hearing threshold and data-logging records.

Children’s ageFather’s ageMother’s ageFamily sizeDuration of HA usage (months)Parent’s estimation of daily use (hours)
Data log for 3 months0.414**0.1230.1920.0600.325**0.623*
Data log for 6 months0.406**0.0640.2050.0140.416**0.772**
Aided PTA−0.416**−0.146−0.1890.202−0.451**−0.312*
Aided SDT−0.392**−0.220-0.2020.157−0.381**−0.275*

Correlation coefficients are shown. HA: hearing aid, PTA: pure tone average for 4 frequencies (500, 1000, 2000, and 4000 Hz); SDT: speech detection threshold, **Correlation is significant at the 0.01 level (2-tailed). *Correlation is significant at the 0.05 level (2-tailed).