Skip to main content

Main menu

  • Home
  • Content
    • Latest
    • Archive
    • home
  • Info for
    • Authors
    • Reviewers
    • Subscribers
    • Institutions
    • Advertisers
    • Join SMJ
  • About Us
    • About Us
    • Editorial Office
    • Editorial Board
  • More
    • Advertising
    • Alerts
    • Feedback
    • Folders
    • Help
  • Other Publications
    • NeuroSciences Journal

User menu

  • My alerts
  • Log in

Search

  • Advanced search
Saudi Medical Journal
  • Other Publications
    • NeuroSciences Journal
  • My alerts
  • Log in
Saudi Medical Journal

Advanced Search

  • Home
  • Content
    • Latest
    • Archive
    • home
  • Info for
    • Authors
    • Reviewers
    • Subscribers
    • Institutions
    • Advertisers
    • Join SMJ
  • About Us
    • About Us
    • Editorial Office
    • Editorial Board
  • More
    • Advertising
    • Alerts
    • Feedback
    • Folders
    • Help
  • Follow psmmc on Twitter
  • Visit psmmc on Facebook
  • RSS
Research ArticleOriginal Article
Open Access

Comparison of proseal laryngeal mask and endotracheal tube for airway safety in pediatric strabismus surgery.

Rauf Gul, Sitki Goksu, Berna K. Ugur, Levent Sahin, Senem Koruk, Seydi Okumus and Ibrahim Erbagci
Saudi Medical Journal April 2012, 33 (4) 388-394;
Rauf Gul
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sitki Goksu
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Berna K. Ugur
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Levent Sahin
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Senem Koruk
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Seydi Okumus
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ibrahim Erbagci
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • eLetters
  • Info & Metrics
  • PDF
Loading

Abstract

OBJECTIVES: To compare proseal laryngeal mask airway (PLMA) with an endotracheal tube (ET) for airway safety, maintained ease of insertion, and hemodynamic stability in pediatric strabismus surgery (PSS).

METHODS: This prospective-randomized clinical study was carried out in the Department of Anesthesiology, Faculty of Medicine, Gaziantep University, Turkey between April 2008 and July 2009. Eighty American Society of Anesthesiology (ASA) I-II children, weight 10-30 kg, aged between 1-12 years undergoing PSS were selected. The anesthesia was induced with 8% sevoflurane, 50% nitrous oxide/oxygen mixture, and a neuromuscular blockade with 0.5 mg/kg atracurium in both groups. After a sufficient dosage of anesthesia, the patients were randomized into 2 groups (Group P: PLMA, n= 40, Group T: ET, n=40) and an airway management device; either a PLMA or ET was inserted. The number of placement attempts, placement success or failure, success or failure of a gastric suction tube placement during the procedures and perioperative complications were assessed.

RESULTS: Thirty-eight patients (95%) in the PLMA group, 39 (97.5%) patients in the ET group were successfully placed with a PLMA and ET on the first attempt (p>0.05). There were no statistically significant differences in the hemodynamic parameters, end-tidal carbon dioxide, and complications.

CONCLUSIONS: This study revealed that PLMA may offer an alternative airway to ET wherein positive pressure ventilation was the preferred choice for children undergoing PSS.

  • Copyright: © Saudi Medical Journal

This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial License (CC BY-NC), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

PreviousNext
Back to top

In this issue

Saudi Medical Journal: 33 (4)
Saudi Medical Journal
Vol. 33, Issue 4
1 Apr 2012
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author
Download PDF
Email Article

Thank you for your interest in spreading the word on Saudi Medical Journal.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Comparison of proseal laryngeal mask and endotracheal tube for airway safety in pediatric strabismus surgery.
(Your Name) has sent you a message from Saudi Medical Journal
(Your Name) thought you would like to see the Saudi Medical Journal web site.
Citation Tools
Comparison of proseal laryngeal mask and endotracheal tube for airway safety in pediatric strabismus surgery.
Rauf Gul, Sitki Goksu, Berna K. Ugur, Levent Sahin, Senem Koruk, Seydi Okumus, Ibrahim Erbagci
Saudi Medical Journal Apr 2012, 33 (4) 388-394;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Comparison of proseal laryngeal mask and endotracheal tube for airway safety in pediatric strabismus surgery.
Rauf Gul, Sitki Goksu, Berna K. Ugur, Levent Sahin, Senem Koruk, Seydi Okumus, Ibrahim Erbagci
Saudi Medical Journal Apr 2012, 33 (4) 388-394;
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • eLetters
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Exploring communication challenges with children and parents among pharmacists in Saudi Arabia
  • Exploring hypothyroidism’s effects on lipid profiles
  • Assessment of asthma control levels in a tertiary hospital
Show more Original Article

Similar Articles

CONTENT

  • home

JOURNAL

  • home

AUTHORS

  • home
Saudi Medical Journal

© 2025 Saudi Medical Journal Saudi Medical Journal is copyright under the Berne Convention and the International Copyright Convention.  Saudi Medical Journal is an Open Access journal and articles published are distributed under the terms of the Creative Commons Attribution-NonCommercial License (CC BY-NC). Readers may copy, distribute, and display the work for non-commercial purposes with the proper citation of the original work. Electronic ISSN 1658-3175. Print ISSN 0379-5284.

Powered by HighWire