Skip to main content

Main menu

  • Home
  • Content
    • Latest
    • Archive
    • home
  • Info for
    • Authors
    • Reviewers
    • Subscribers
    • Institutions
    • Advertisers
    • Join SMJ
  • About Us
    • About Us
    • Editorial Office
    • Editorial Board
  • More
    • Advertising
    • Alerts
    • Feedback
    • Folders
    • Help
  • Other Publications
    • NeuroSciences Journal

User menu

  • My alerts
  • Log in
  • Log out

Search

  • Advanced search
Saudi Medical Journal
  • Other Publications
    • NeuroSciences Journal
  • My alerts
  • Log in
  • Log out
Saudi Medical Journal

Advanced Search

  • Home
  • Content
    • Latest
    • Archive
    • home
  • Info for
    • Authors
    • Reviewers
    • Subscribers
    • Institutions
    • Advertisers
    • Join SMJ
  • About Us
    • About Us
    • Editorial Office
    • Editorial Board
  • More
    • Advertising
    • Alerts
    • Feedback
    • Folders
    • Help
  • Follow psmmc on Twitter
  • Visit psmmc on Facebook
  • RSS
Research ArticleOriginal Article
Open Access

Development of a new high performance liquid chromatography method for measurement of coenzyme Q10 in healthy blood plasma

Omar F. Abdul-Rasheed and Yahya Y. Farid
Saudi Medical Journal September 2009, 30 (9) 1138-1143;
Omar F. Abdul-Rasheed
Department of Chemistry and Biochemistry, College of Medicine, Al-Nahrain University, Al-Kadhmiya, PO Box 70027, Baghdad, Iraq. Tel. +964 (790) 1885283. E-mail: [email protected]/[email protected]
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected] [email protected]
Yahya Y. Farid
Department of Chemistry and Biochemistry, College of Medicine, Al-Nahrain University, Al-Kadhmiya, PO Box 70027, Baghdad, Iraq. Tel. +964 (790) 1885283. E-mail: [email protected]/[email protected]
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected] [email protected]
  • Article
  • eLetters
  • Info & Metrics
  • PDF
Loading

Abstract

OBJECTIVE: To improve a new high performance liquid chromatography (HPLC) method for coenzyme Q10 (CoQ10) measurement in human plasma.

METHODS: We conducted this study in the Chemistry and Biochemistry Department, College of Medicine, Al-Nahrain University, Baghdad, Iraq from September 2004 to July 2005. Sixty healthy volunteers aged 28.51±7.30 years were participated in this study. All participants were non-smokers and under no any treatment for the last 3 days and fast for 12 hours before analysis. Coenzyme Q10 levels were measured by improved isocratic reversed phase HPLC technique after one-step ice-cold 1-propanol extraction step.

RESULTS: The ultra violet (UV) detection, developed HPLC method gives a good linearity range between 0.1-4.0 mg/L. The coefficients of variations (CVs%) of within-day precision for CoQ10 in human plasma were 0.2-3.90%. Analytical recoveries were 95.5-101.30%, whereas the average CV% of CoQ10 reproducibility was 0.959%.

CONCLUSION: A new improved rapid, precise, and sensitive HPLC method for the quantitation of CoQ10 is suitable for analysis of blood plasma samples.

  • Copyright: © Saudi Medical Journal

This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

PreviousNext
Back to top

In this issue

Saudi Medical Journal: 30 (9)
Saudi Medical Journal
Vol. 30, Issue 9
1 Sep 2009
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author
Download PDF
Email Article

Thank you for your interest in spreading the word on Saudi Medical Journal.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Development of a new high performance liquid chromatography method for measurement of coenzyme Q10 in healthy blood plasma
(Your Name) has sent you a message from Saudi Medical Journal
(Your Name) thought you would like to see the Saudi Medical Journal web site.
Citation Tools
Development of a new high performance liquid chromatography method for measurement of coenzyme Q10 in healthy blood plasma
Omar F. Abdul-Rasheed, Yahya Y. Farid
Saudi Medical Journal Sep 2009, 30 (9) 1138-1143;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Development of a new high performance liquid chromatography method for measurement of coenzyme Q10 in healthy blood plasma
Omar F. Abdul-Rasheed, Yahya Y. Farid
Saudi Medical Journal Sep 2009, 30 (9) 1138-1143;
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • eLetters
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Longitudinal analysis of foodborne disease outbreaks in Saudi Arabia
  • Psychological stress and its association with bronchial asthma in Saudi Arabia
  • The factors affecting comfort and the comfort levels of patients hospitalized in the coronary intensive care unit
Show more Original Article

Similar Articles

CONTENT

  • home

JOURNAL

  • home

AUTHORS

  • home
Saudi Medical Journal

© 2025 Saudi Medical Journal Saudi Medical Journal is copyright under the Berne Convention and the International Copyright Convention.  Saudi Medical Journal is an Open Access journal and articles published are distributed under the terms of the Creative Commons Attribution-NonCommercial License (CC BY-NC). Readers may copy, distribute, and display the work for non-commercial purposes with the proper citation of the original work. Electronic ISSN 1658-3175. Print ISSN 0379-5284.

Powered by HighWire