Skip to main content

Main menu

  • Home
  • Content
    • Latest
    • Archive
    • home
  • Info for
    • Authors
    • Reviewers
    • Subscribers
    • Institutions
    • Advertisers
    • Join SMJ
  • About Us
    • About Us
    • Editorial Office
    • Editorial Board
  • More
    • Advertising
    • Alerts
    • Feedback
    • Folders
    • Help
  • Other Publications
    • NeuroSciences Journal

User menu

  • My alerts
  • Log in

Search

  • Advanced search
Saudi Medical Journal
  • Other Publications
    • NeuroSciences Journal
  • My alerts
  • Log in
Saudi Medical Journal

Advanced Search

  • Home
  • Content
    • Latest
    • Archive
    • home
  • Info for
    • Authors
    • Reviewers
    • Subscribers
    • Institutions
    • Advertisers
    • Join SMJ
  • About Us
    • About Us
    • Editorial Office
    • Editorial Board
  • More
    • Advertising
    • Alerts
    • Feedback
    • Folders
    • Help
  • Follow psmmc on Twitter
  • Visit psmmc on Facebook
  • RSS
Research ArticleOriginal Article
Open Access

Use of ultrasound guidance in central venous catheter placement by emergency physicians in Saudi Arabia

Zohair A. Al Aseri, Reema M. Al Hussein, Mohammed A. Malabarey, Bader A. Al Yahya, Faisal A. Al Moaiqel, Mariam A. Al Ansari and Khaled N. Alrajhi
Saudi Medical Journal July 2020, 41 (7) 698-702; DOI: https://doi.org/10.15537/smj.2020.7.25162
Zohair A. Al Aseri
From the Departments of Emergency Medicine and Critical Care (Al Aseri), College of Medicine, King Saud University; from the Department of Emergency Medicine (Malabarey, Al Yahya), Medical City, King Saud University; from the College of Medicine (Al Hussein), Dar Aluloom University; from the College of Medicine (Al Moaiqel, Alrajhi), King Saud Bin Abdulaziz University for Health Sciences; from the Department of Emergency Medicine (Alrajhi), Health Affairs, Ministry of National Guard, Riyadh; and from the Department of Internal Medicine (Al Ansari), Intensive Care Unit, Al Imam Abdulrahman Bin Faisal Hospital, Health Affairs, Ministry of National Guard, Dammam, Kingdom of Saudi Arabia
MD, FRCP
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected]
Reema M. Al Hussein
From the Departments of Emergency Medicine and Critical Care (Al Aseri), College of Medicine, King Saud University; from the Department of Emergency Medicine (Malabarey, Al Yahya), Medical City, King Saud University; from the College of Medicine (Al Hussein), Dar Aluloom University; from the College of Medicine (Al Moaiqel, Alrajhi), King Saud Bin Abdulaziz University for Health Sciences; from the Department of Emergency Medicine (Alrajhi), Health Affairs, Ministry of National Guard, Riyadh; and from the Department of Internal Medicine (Al Ansari), Intensive Care Unit, Al Imam Abdulrahman Bin Faisal Hospital, Health Affairs, Ministry of National Guard, Dammam, Kingdom of Saudi Arabia
Medical Student
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mohammed A. Malabarey
From the Departments of Emergency Medicine and Critical Care (Al Aseri), College of Medicine, King Saud University; from the Department of Emergency Medicine (Malabarey, Al Yahya), Medical City, King Saud University; from the College of Medicine (Al Hussein), Dar Aluloom University; from the College of Medicine (Al Moaiqel, Alrajhi), King Saud Bin Abdulaziz University for Health Sciences; from the Department of Emergency Medicine (Alrajhi), Health Affairs, Ministry of National Guard, Riyadh; and from the Department of Internal Medicine (Al Ansari), Intensive Care Unit, Al Imam Abdulrahman Bin Faisal Hospital, Health Affairs, Ministry of National Guard, Dammam, Kingdom of Saudi Arabia
MD, FRCP
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Bader A. Al Yahya
From the Departments of Emergency Medicine and Critical Care (Al Aseri), College of Medicine, King Saud University; from the Department of Emergency Medicine (Malabarey, Al Yahya), Medical City, King Saud University; from the College of Medicine (Al Hussein), Dar Aluloom University; from the College of Medicine (Al Moaiqel, Alrajhi), King Saud Bin Abdulaziz University for Health Sciences; from the Department of Emergency Medicine (Alrajhi), Health Affairs, Ministry of National Guard, Riyadh; and from the Department of Internal Medicine (Al Ansari), Intensive Care Unit, Al Imam Abdulrahman Bin Faisal Hospital, Health Affairs, Ministry of National Guard, Dammam, Kingdom of Saudi Arabia
MD, FRCP
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Faisal A. Al Moaiqel
From the Departments of Emergency Medicine and Critical Care (Al Aseri), College of Medicine, King Saud University; from the Department of Emergency Medicine (Malabarey, Al Yahya), Medical City, King Saud University; from the College of Medicine (Al Hussein), Dar Aluloom University; from the College of Medicine (Al Moaiqel, Alrajhi), King Saud Bin Abdulaziz University for Health Sciences; from the Department of Emergency Medicine (Alrajhi), Health Affairs, Ministry of National Guard, Riyadh; and from the Department of Internal Medicine (Al Ansari), Intensive Care Unit, Al Imam Abdulrahman Bin Faisal Hospital, Health Affairs, Ministry of National Guard, Dammam, Kingdom of Saudi Arabia
Medical Student
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mariam A. Al Ansari
From the Departments of Emergency Medicine and Critical Care (Al Aseri), College of Medicine, King Saud University; from the Department of Emergency Medicine (Malabarey, Al Yahya), Medical City, King Saud University; from the College of Medicine (Al Hussein), Dar Aluloom University; from the College of Medicine (Al Moaiqel, Alrajhi), King Saud Bin Abdulaziz University for Health Sciences; from the Department of Emergency Medicine (Alrajhi), Health Affairs, Ministry of National Guard, Riyadh; and from the Department of Internal Medicine (Al Ansari), Intensive Care Unit, Al Imam Abdulrahman Bin Faisal Hospital, Health Affairs, Ministry of National Guard, Dammam, Kingdom of Saudi Arabia
MD, FRCSI
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Khaled N. Alrajhi
From the Departments of Emergency Medicine and Critical Care (Al Aseri), College of Medicine, King Saud University; from the Department of Emergency Medicine (Malabarey, Al Yahya), Medical City, King Saud University; from the College of Medicine (Al Hussein), Dar Aluloom University; from the College of Medicine (Al Moaiqel, Alrajhi), King Saud Bin Abdulaziz University for Health Sciences; from the Department of Emergency Medicine (Alrajhi), Health Affairs, Ministry of National Guard, Riyadh; and from the Department of Internal Medicine (Al Ansari), Intensive Care Unit, Al Imam Abdulrahman Bin Faisal Hospital, Health Affairs, Ministry of National Guard, Dammam, Kingdom of Saudi Arabia
MD, FRCP
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • eLetters
  • Info & Metrics
  • References
  • PDF
Loading

Abstract

Objectives: To determine the ultrasound guidance for central venous catheter (USG-CVC) placement rate of emergency physicians (EPs) in Kingdom of Saudi Arabia.

Methods: A cross-sectional survey study regarding the respondents’ demographic profiles, formal and informal training in USG-CVC placement, experiences, and attitudes towards the procedure was emailed to all EPs registered with the Saudi Commission for Health Specialties (SCFHS) between October and December 2018.

Results: In total, 234/350 SCFHS-registered EPs completed the survey; the response rate was 66.9%. Most respondents (70.5%) were board-certified in emergency medicine (EM). Ninety percent indicated that US device for CVC placement assistance was available. Most EPs (78.2%) had performed USG-CVC placement; the US usage rate correlated significantly with recent graduation from residency (p=0.048). In total, 83.3% received formal training during residency. Of the 234 respondents, 53.8% felt extremely comfortable with CVC placement with USG and 19.7% without USG (p<0.01). Nevertheless, most respondents desired further USG-CVC training.

Conclusion: Despite existing evidence and a consensus on its superiority over the landmark technique, USG-CVC placement has not been adopted by a small proportion of EPs into clinical practice. Formal training, education, and institutional provision of permanent onsite US machines may address any barriers.

  • central venous catheters
  • ultrasonography
  • physicians
  • emergency medicine

The placement of a central venous catheter (CVC) has become an integral part of emergency medicine (EM) practice for critically ill patients.1,2 A previous observational cohort study reported a complication rate of 34% associated with CVC placement, with the majority of complications being related to placement failure.3 Moreover, a recent systematic review showed that the rate of adverse events such as arterial puncture, hematoma, and hemothorax resulting from CVC placement using the landmark technique was 13.5%.2 The utilization of ultrasonography during CVC placement is associated with a significant reduction in the relative risk of complications and an increase in the first-attempt success rate.2,4-7 In addition, real-time sonographic guidance for central venous access is strongly recommended by the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) guidelines as a key safety measure.8

Despite this evidence, there is limited incorporation of ultrasound guidance for central venous catheter (USG-CVC) placement in clinical practice by some emergency physicians (EPs). Indeed, in a recent study, 44% of respondents stated that they never used USG-CVC placement.9 Evidence suggests that EPs consider a lack of training to be a barrier to the widespread implementation of USG-CVC placement.10

The aim of this study is to survey practicing EPs in Kingdom of Saudi Arabia (KSA) with regard to the frequency of USG-CVC placement and factors that may be associated with its use.

Methods

A cross-sectional survey study targeting all EPs practicing in KSA was conducted. Participants were included if they are EPs practicing in KSA. For the purpose of this study, a physician would be considered an EP if they are in or have completed a residency program in EM or are licensed physicians classified by the Saudi Commission for Health Specialties as emergency physicians. Data was collected over a 2-month period from October to December of 2018. Emergency physicians at various hospitals and at various stages of their careers were invited to participate in the study. An email invitation containing the consent form and the survey material was sent via SurveyMonkey through the Saudi Commission for Health Specialties targeting 350 EPs. The sample size was calculated to be 184 using a 95% confidence level, 5% confidence interval, and power of 80.

The survey’s face validity was established through a review of a group of board-certified, university-affiliated EPs with several years of clinical experience. A small-scale feasibility/pilot study was conducted to determine the survey’s reliability.

The survey contained direct questions to assess the frequency of ultrasound guidance for CVC placement. We hypothesize that factors associated with or barriers to USG be around demographics, training, clinical experience, attitudes, and resources. This was covered in the survey with questions on the demographic profiles of the respondents (gender, nationality, place of residence, type of hospital, number of years in practice, and number of clinical shifts), formal and informal training on USG-CVC placement, interest in further training, experience with CVCs, attitudes and comfort regarding USG-CVC placement. Likert scales were used to measure the participants’ level of agreement regarding USG-CVC placement (1: strongly disagree to 5: strongly agree), their comfort in placing CVCs (0: extremely uncomfortable to 5: extremely comfortable), and their views and judgment toward the use of medical technology and uncertainty in diagnosis (1: strongly agree to 9: strongly disagree). To determine correlations with USG-CVC placement, the respondents were divided into 5 groups based on the percentage of CVCs that they had placed under US guidance: 0-20%, 21-40%, 41-60%, 61-80%, and 81-100%.

The data collected from SurveyMonkey was exported as a worksheet and analyzed using Statistical Package for Social Sciences (SPSS) version 23.0 (IBM Corp., Armonk, NY, USA). The results are expressed as numbers and percentages for categorical variables and as the mean and standard deviation for continuous variables. A Chi-square (χ2) test was used to compare proportions between 2 groups. The Pearson correlation test was applied to determine the correlation between variables. Finally, univariate and multivariate regression analyses were performed to determine significant factors related to the non-use of USG-CVCs. To determine barriers carrying out USG-CVC placement on the basis, all relevant variables based on p-values (p<0.05) were entered into a logistic regression model with USG-CVC placement as the dependent variable.

The study was approved by the Institutional Review Board (IRB), King Fahad Medical City at the Ministry of Health, Riyadh, KSA. It was found that the study compliant with the Principles of Helsinki Declaration. Participation in this study was voluntary and participants were informed about the aim, purpose, and procedure of the study. The participants were not offered incentives to participate in the study.

Results

In total, 350 emails were sent via the SCFHS to EPs, 234 of whom responded to the survey (response rate: 66.9%). The majority of respondents (70.5%) were board-certified in EM, and the remaining 29.5% were residents. Of the 234 respondents, the majority were practicing in a government or Ministry of Health hospitals (45.3%) (Table 1).

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 1

Demographic profiles of the emergency physicians surveyed (N=234).

Availability of US machines and use of USG-CVC placement technique

Most respondents (90.6%) indicated that at least one US device for CVC placement assistance was available. One US machine was available for 54 respondents (23.1%), 2 machines for 83 respondents (35.5%), 3 machines for 49 respondents (20.9%), 4 machines for 20 respondents (8.5%), and 6 or more machines for 7 respondents (2.6%). Table 2 shows the percentage of CVC placements in which US guidance was used. Attending physicians supervised 155 (66.2%) of the placements; other physicians, fellows, or residents supervised the remaining placements.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 2

The percentage of CVC placements conducted with USG.

Formal and informal training

ome form of formal training in USG-CVC placement at various stages of residency training was received by 195 respondents (83.3%). These included didactic or video-only training without hands-on training, experience with US-guided dynamic visualization without needle placement, and USG-CVC placement on a simulation model. Informal training modalities included hands-off observation, maneuvering the US device with or without insertion of a catheter. Thirty-nine (16.7%) respondents did not have any type of formal training on USG-CVC placement (Table 3).

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 3

Formal and informal training on USG-CVC placement.

Attitudes and levels of comfort in placing CVCs with or without US guidance

More responders felt extremely comfortable with USG-CVC placement than with CVC placement without USG (53.8% vs. 19.7%, p<0.01) (Table 4). The majority of respondents strongly agree/agree that USG-CVC placement is easier to perform, is faster, reduces mechanical complications, results in fewer placement failures, and is useful for patients with difficult landmarks (Table 5).

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 4

Levels of comfort in placing central venous catheter with and without USG.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 5

The respondents’ levels of agreement on the advantage of using USG over the landmark method for CVC placement.

Correlates of USG-CVC placement

Most EPs (78.2%) had performed USG-CVC placement. Ultrasound guidance for central venous catheter placement correlated significantly with fewer years from graduation of residency (r=0.130, p=0.048), having attended formal courses on their own (r=0.196, p=0.003) and courses provided by the hospital (r=0.161, p=0.014), the availability of a portable US machine to assist EPs in CVC placement (r=0.170, p=0.009), comfort in placing CVCs with US guidance (r=0.253, p<0.001), and perceptions that USG-CVC placement is faster (r=0.272, p<0.001), reduces mechanical complications (r=0.297, p<0.001) and infectious complications (r=0.172, p=0.008), results in fewer placement failures (r=0.355, p<0.001), is useful when the landmark method is unsuccessful (r=0.175, p=0.007), is useful for patients with coagulopathy (r=0.154, p=0.018), is more convenient (r=0.277, p<0.001), and is cost effective (r=0.237, p<0.001).

Discussion

The use of USG-CVCs has been the subject of several research papers and has been found to decrease morbidity and complications caused by the traditional landmark method.2-6,11-13 Our survey showed that most EPs in KSA agree with the published literature. Despite these findings, 21.8% of the respondents had never/seldom used the US in CVC placement. In a cross-sectional survey of practicing EPs in the United States, 44% had never used US guidance in placing CVCs.9 However, fewer physicians in our survey had never/seldom used USG in CVC placement than in previous studies. Based on the literature, we believe that every CVC should be inserted under USG and that every effort should target barriers to US use in CVC placement. Several barriers to USG-CVC placement have been identified. Matera et al,14 reported common barriers to routine US use in CVC placement, namely, not having completed a US course and perceiving the procedure as time-consuming. In another survey, Scholten et al,15 found that working in a non-academic hospital and more years of experience were barriers to USG-CVC placement. Two other surveys showed that insufficient training and the limited availability of equipment are barriers to US use.9,16 In accordance with previous surveys, our respondents identified the lack of formal training and unavailability of a US machine as barriers to USG-CVC placement.

Study limitations

The limitation of this study is that the survey responses were self-reported; indeed, the responses may not reflect the true competence of the respondents. Additionally, the results may have been influenced by bias, and the questions may have been unclear to some of the respondents. Furthermore, our results may not be generalizable because the majority of our respondents were in their early years of practice.

In conclusion, we were able to highlight the use of the USG-CVC placement technique by EPs, the nature and benefits of training on USG-CVC placement, and the respondents’ perceptions and attitudes toward CVC placement.

Despite existing evidence and a consensus regarding the superiority of USG-CVC placement over the landmark technique, a small proportion of EPs have been unable to translate evidence into clinical practice. Future studies on the effectiveness of current training and impact of various forms of formal or informal education on adoption and best practices for institutional provisions for placement of US machines on-site may address any barriers.

Acknowledgment

The authors gratefully acknowledge American Journal Editors (https://www.aje.com) for the English language editing.

Footnotes

  • Disclosure. Authors have no conflict of interests, and the work was not supported or funded by any drug company.

  • Received February 10, 2020.
  • Accepted June 10, 2020.
  • Copyright: © Saudi Medical Journal

This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

References

  1. ↵
    1. Oulego-Erroz I,
    2. González-Cortes R,
    3. García-Soler P,
    4. Balaguer-Gargallo M,
    5. Frías-Pérez M,
    6. Mayordomo-Colunga J,
    7. et al.
    (2018) Ultrasound-guided or landmark techniques for central venous catheter placement in critically ill children. Intensive Care Med 44:61–72.
    OpenUrlPubMed
  2. ↵
    1. Brass P,
    2. Hellmich M,
    3. Kolodziej L,
    4. Schick G,
    5. Smith AF
    (2015) Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization. Cochrane Database Syst Rev 1:CD006962.
    OpenUrlPubMed
  3. ↵
    1. Eisen LA,
    2. Narasimhan M,
    3. Berger JS,
    4. Mayo PH,
    5. Rosen MJ,
    6. Schneider RF
    (2006) Mechanical complications of central venous catheters. J Intensive Care Med 21:40–46.
    OpenUrlCrossRefPubMed
  4. ↵
    1. Wu SY,
    2. Ling Q,
    3. Cao LH,
    4. Wang J,
    5. Xu MX,
    6. Zeng WA
    (2013) Real-time two-dimensional ultrasound guidance for central venous cannulation:a meta-analysis. Anesthesiology 118:361–375.
    OpenUrlCrossRefPubMed
    1. Palepu GB,
    2. Deven J,
    3. Subrahmanyam M,
    4. Mohan S
    (2009) Impact of ultrasonography on central venous catheter insertion in intensive care. Indian J Radiol Imaging 19:191–198.
    OpenUrlCrossRefPubMed
  5. ↵
    1. Lau CS,
    2. Chamberlain RS
    (2016) Ultrasound-guided central venous catheter placement increases success rates in pediatric patients:a meta-analysis. Pediatr Res 80:178–184.
    OpenUrl
  6. ↵
    1. Froehlich CD,
    2. Rigby MR,
    3. Rosenberg ES,
    4. Li R,
    5. Roerig PJ,
    6. Easley KA,
    7. et al.
    (2009) Ultrasound-guided central venous catheter placement decreases complications and decreases placement attempts compared with the landmark technique in patients in a pediatric intensive care unit. Crit Care Med 37:1090–1096.
    OpenUrlCrossRefPubMed
  7. ↵
    1. Jenssen C,
    2. Brkljacic B,
    3. Hocke M,
    4. Ignee A,
    5. Piscaglia F,
    6. Radzina M,
    7. et al.
    (2016) EFSUMB guidelines on interventional ultrasound (INVUS), Part VI - ultrasound-guided vascular interventions. Ultraschall Med 37:473–476.
    OpenUrl
  8. ↵
    1. Buchanan MS,
    2. Backlund B,
    3. Liao MM,
    4. Sun J,
    5. Cydulka RK,
    6. Smith-Coggins R,
    7. et al.
    (2014) Use of ultrasound guidance for central venous catheter placement:survey from the american board of emergency medicine longitudinal study of emergency physicians. Acad Emerg Med 21:416–421.
    OpenUrlCrossRefPubMed
  9. ↵
    1. Backlund BH,
    2. Hopkins E,
    3. Kendall JL
    (2012) Ultrasound guidance for central venous access by emergency physicians in colorado. West J Emerg Med 13:320–325.
    OpenUrlPubMed
  10. ↵
    1. Leung J,
    2. Duffy M,
    3. Finckh A
    (2006) Real-time ultrasonographically-guided internal jugular vein catheterization in the emergency department increases success rates and reduces complications:a randomized, prospective study. Ann Emerg Med 48:540–547.
    OpenUrlCrossRefPubMed
    1. Theodoro D,
    2. Bausano B,
    3. Lewis L,
    4. Evanoff B,
    5. Kollef M
    (2010) A descriptive comparison of ultrasound-guided central venous cannulation of the internal jugular vein to landmark-based subclavian vein cannulation. Acad Emerg Med 17:416–422.
    OpenUrlPubMed
  11. ↵
    1. Saugel B,
    2. Scheeren TWL,
    3. Teboul JL
    (2017) Ultrasound-guided central venous catheter placement:a structured review and recommendations for clinical practice. Crit Care 21:225.
    OpenUrlPubMed
  12. ↵
    1. Matera JT,
    2. Egerton-Warburton D,
    3. Meek R
    (2010) Ultrasound guidance for central venous catheter placement in Australasian emergency departments:potential barriers to more widespread use. Emerg Med Australas 22:514–523.
    OpenUrlCrossRefPubMed
  13. ↵
    1. Scholten HJ,
    2. Ten Bloemendal E,
    3. Botter B,
    4. Korsten HHM,
    5. Bouwman RA
    (2019) Barriers to ultrasound guidance for central venous access:a survey among Dutch intensivists and anaesthesiologists. J Clin Monit Comput 33:1023–1031.
    OpenUrl
  14. ↵
    1. Zaver F,
    2. Boniface K,
    3. Wachira B,
    4. Wanjiku G,
    5. Shokoohi H
    (2018) International scope of emergency ultrasound:Barriers in applying ultrasound to guide central line placement by providers in Nairobi, Kenya. Emerg Med Int 2018:7328465.
    OpenUrl
View Abstract
PreviousNext
Back to top

In this issue

Saudi Medical Journal: 41 (7)
Saudi Medical Journal
Vol. 41, Issue 7
1 Jul 2020
  • Table of Contents
  • Cover (PDF)
  • Index by author
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on Saudi Medical Journal.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Use of ultrasound guidance in central venous catheter placement by emergency physicians in Saudi Arabia
(Your Name) has sent you a message from Saudi Medical Journal
(Your Name) thought you would like to see the Saudi Medical Journal web site.
Citation Tools
Use of ultrasound guidance in central venous catheter placement by emergency physicians in Saudi Arabia
Zohair A. Al Aseri, Reema M. Al Hussein, Mohammed A. Malabarey, Bader A. Al Yahya, Faisal A. Al Moaiqel, Mariam A. Al Ansari, Khaled N. Alrajhi
Saudi Medical Journal Jul 2020, 41 (7) 698-702; DOI: 10.15537/smj.2020.7.25162

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Use of ultrasound guidance in central venous catheter placement by emergency physicians in Saudi Arabia
Zohair A. Al Aseri, Reema M. Al Hussein, Mohammed A. Malabarey, Bader A. Al Yahya, Faisal A. Al Moaiqel, Mariam A. Al Ansari, Khaled N. Alrajhi
Saudi Medical Journal Jul 2020, 41 (7) 698-702; DOI: 10.15537/smj.2020.7.25162
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • Methods
    • Results
    • Discussion
    • Acknowledgment
    • Footnotes
    • References
  • Figures & Data
  • eLetters
  • References
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Prolonged flight exposure and its effects on sinonasal health among aircrew members
  • Identifying individuals at risk of post-stroke depression
  • Hematological parameters in recent and past dengue infections in Jazan Province, Saudi Arabia
Show more Original Article

Similar Articles

Keywords

  • central venous catheters
  • ultrasonography
  • physicians
  • emergency medicine

CONTENT

  • home

JOURNAL

  • home

AUTHORS

  • home
Saudi Medical Journal

© 2025 Saudi Medical Journal Saudi Medical Journal is copyright under the Berne Convention and the International Copyright Convention.  Saudi Medical Journal is an Open Access journal and articles published are distributed under the terms of the Creative Commons Attribution-NonCommercial License (CC BY-NC). Readers may copy, distribute, and display the work for non-commercial purposes with the proper citation of the original work. Electronic ISSN 1658-3175. Print ISSN 0379-5284.

Powered by HighWire