Abstract
OBJECTIVE: This study was performed with the aim of evaluating the usefulness of 3 dimensional double-echo steady state sequences in examining the internal derangements of the knee. Arthroscopy was used as a referral standard.
METHODS: The study was performed in the Radiology and Arthroscopy Departments of King's College Hospital, London, United Kingdom, during a 6-month period from January 1997 to June 1997. All patients who had knee magnetic resonance imaging within 3 months of arthroscopy were retrospectively studied. Thirty-three patients fulfilled these criteria and were selected.
RESULTS: Three dimensional double-echo steady state sequences produced sensitivity for detecting meniscal tears of 87.5% for medial menisci (MM) and 75% for lateral menisci (LM). Specificity was 76% for MM and 96% for LM; positive predictive value (PPV) was 46.1% for MM and 85.7% for LM and negative predictive value (NPV) of 95% for MM and 96% for LM. The sensitivity for the anterior cruciate ligament was 83.3%, specificity was 77.7%, PPV was 45.4% and NPV was 95.4%.
CONCLUSION: Three dimensional double-echo steady state sequences are useful in evaluating internal derangement of the knee, especially in advanced cartilage lesions.