Abstract
Esophageal foreign body (EFB) ingestion is of ubiquitous occurrence in pediatric population. Diagnosis and precise localization of non-radio opaque FB poses considerable challenge. Delayed presentation, poor history, and inconclusive esophagoscopic findings often lead to diagnostic delay. Multidetector computed tomography (MDCT) could be a great option in these situations. We present a case of EFB in a child who presented with failure to thrive, had negative fibreoptic endoscopy, ultimately diagnosed conclusively on MDCT examination.
- Copyright: © Saudi Medical Journal
This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.